120W/48V Industrial DIN rail power supply
120W/48V Industrial DIN rail power supply
TECHNICAL SPECIFICATION
Model |
GWS-P3000-DP120-48 |
Output |
|
Group of Output |
1 |
DC Voltage |
48VDC |
Output Voltage Factory Setting |
48.00-48.2VDC (Vin: 220VAC / Load: 0A) |
Output Rated Current |
2.5A |
Output Current Range |
0-2.5A |
Rated Output Power |
120W |
Total Peak Output Power |
180W (sustainable time 10S/220VAC) |
Peak Output Current |
3.7A (sustainable time 10S/220VAC) |
Ripple Noise |
Peak-to-peak value ≤100mV. (Measurement method: The terminal should be connected in parallel with 0.1uF and 47uF capacitors, and the measurement should be performed at a bandwidth of 20MHz) |
Output Voltage Range |
47-56VDC |
Stabilized Voltage Precision |
±1% (@ 90-264VAC input, 100% load) |
Line Regulation |
±0.5% (@ 90-264VAC input, 100% load) |
Load Regulation |
±1% (@90-264VAC input, 0-100% load) |
Output Start Time |
<2S @ nominal input (100% load ) |
Output Hold Time |
>20ms @ 115VAC, >50ms @ 230VAC (100% load ) |
Voltage Overshoot |
≤5.0% |
Input |
|
Input Voltage Range |
90-264VAC |
Input Rated Voltage Range |
100-240VAC |
Frequency Range |
47Hz-63Hz |
Rated Frequency |
50Hz/60Hz |
Starting Voltage |
90VAC |
Efficiency |
>90.0% @115VAC, >91.0% @ 230VAC |
Input Current |
<2.20A @115VAC, <1.10A @ 230VAC |
Start Inrush Current |
<35A @ 115VAC& 230VAC |
Power Factor |
>0.99 @ 115VAC, >0.93 @ 230VAC |
Protection |
|
Output Over Power |
144-180W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) |
Output Over Voltage |
57-70V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. |
Output Over Current |
3-3.75A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.) |
Output Short Circuit |
Use a copper wire with a sufficient cross-sectional area and a length of 15cm±5cm to directly short-circuit at the power output port, which can be short-circuited for a long time, and can be automatically restored after the short-circuit is eliminated. |
Operation Environment |
|
Operation TEMP / Humidity |
-40℃-70℃, 20%-95%RH No condensing |
Storage TEMP / Humidity |
-40℃-85℃, 10%-95%RH No condensing |
Temperature Coefficient |
±0.03%/℃ (0-50℃) |
Vibration |
Frequency range 10-500Hz, acceleration 2G, each sweep cycle 10min. 6 sweep cycles along the X, Y, and Z axes |
Impact |
Acceleration 20G, duration 11ms, 3 shocks along X, Y, and Z axis each |
Altitude |
2000m |
Safety and Electromagnetic Compatibility Standard |
|
Security Standard |
GB4943/EN62368-1 ■Reference □Certification |
Dielectric Strength |
Input—Output: 3KVAC/10mA, Input--Case:1.5KVAC/10mA Output---Case: 0.5KVDC/10mA , Time for each testing is 1min. |
Ground Test |
Test conditions: 32A/2 minutes, Ground impedance: <0.1 ohms. |
leakage Current |
Input to ground ≤3.5mA, Input to output ≤0.25mA (Input 264VAC, Frequency 63Hz) |
Insulation Resistance |
Input-Output: 10M ohms |
Conducted Disturbance |
EN55022, EN55024, FCC PART 15 Class B |
Radiated Interference |
EN55022, EN55024, FCC PART 15 Class B |
Harmaonic Current |
EN61000-3-2 Class D |
Conducted Disturbance |
EN61000-4-6 Level 3 |
Radiation Harassment |
EN61000-4-3 Level 3 Class B |
Power Frequency Harassment |
EN61000-4-8 Level 3 |
Static Harassment |
EN61000-4-2 Level 4 Class B |
fast Burst |
EN61000-4-4 Level 4 Class B |
Lightning Strike (Surge) |
EN61000-4-5 Level 4 Class B |
interrupted Fall |
EN61000-4-11 |
Others |
|
Dimension |
135*121*40mm |
Warranty |
5 years |
OVERVIEW
GWS-P3000-DP120-48 is an economical 120W DIN rail power supply that conforms to German industrial standards. It is suitable for installation on TS-35/7.5, or TS-35/15 rails, using 90VAC to 264VAC input, and complies with EN61000-3-2 Standard on Harmonic Current Specifications Specified by the European Union.
GWS-P3000-DP120-48 adopts a metal shell design to improve heat dissipation consumption. The working efficiency is as high as 90%, and the product can work in an ambient temperature of -40 degrees to 70 degrees under the condition of air circulation. It has a constant current mode overload protection function, suitable for a variety of inductive or capacitive load applications, complete protection functions, and compliance with relevant certifications for industrial control equipment, making it a very competitive power supply solution for industrial applications.
FEATURE
l Meet EMC Standard
l 100% full load aging test
l Power Input: AC90-264V
l Wide operation temperature range: -40℃-70℃
l High efficiency, long life time and high reliability
l Support production for short circuit/over current/over voltage
APPLICATION
l Industrial Control System
l Semiconductor fabrication equipment
l Factory automation
l Electro-mechanical apparatus